Back to catalog
Ubiquiti UA-Intercom-Viewer-3 Intercom Viewer - 3 Pack
UBIQUITI

Ubiquiti UA-Intercom-Viewer-3 Intercom Viewer - 3 Pack

Part No: UA-Intercom-Viewer-3

AED 2,625$713 USD

Authorized B2B supply from DISTI Middle East (UAE & MENA). Genuine stock, project pricing, and fast regional dispatch.

Request a Quote

Specifications

Manufacturer
UBIQUITI
Model
Ubiquiti UA-Intercom-Viewer-3
Manufacturer Part No
UA-Intercom-Viewer-3
Compatible Country
Middle East, Africa, Iran, Dubai
Country of Origin
California

Alternate / cross-brand similar products

AI-matched alternatives based on specifications

Product description & technical overview

UBIQUITI Ubiquiti UA-Intercom-Viewer-3

Mechanical
Dimensions135 x 72 x 31.8 mm (5.3 x 2.8 x 1.3")
Weight168 g (5.9 oz)
Enclosure materialsGlass, polycarbonate
Mount materialAluminum alloy
MountingWall (Included)
Gang box mount (Gang box not included)
Hardware
Networking interface(1) 10/100 Mbps RJ45 port
Management interfaceEthernet
Power methodPoE
UL 294 Power-limited Class 2 PSU
UL 60950-1/62368-1 LPS/PS2 PSU
Supported voltage range44–57V DC
Max. power consumption5W
Display127 mm (5") diagonal
Resolution720 x 1280 (9:16)
Display luminance300 nits (typical)
Touch screen technologyCapacitive multi-touch
Screen orientationPortrait
MicrophoneYes
SpeakerYes
ButtonFactory reset
Ambient operating temperature0 to 40° C (32 to 104° F)
Operating environmentIndoor use only
Ambient operating humidity5 to 95% noncondensing
Software informationThe software version of a product can be checked at https://unifi.ui.com
UL 294 levelDestructive attack: Level I
Line security: Level I
Endurance: Level I
Standby power: Level I
UL 294 statementCompliance with IEEE 802.3 specifications was not verified as part of UL 294.
The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
PoE cabling requirementsCable 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site.
The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm 2 ) for patch cords; 24 AWG (0.21 mm 2 ) for horizontal or riser cable.
CAN/ULC-60839-11-1 GradeGrade assignment: I
CertificationsCE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Document number, and issue date and/or revision levelUA-Intercom-Viewer, V01
Software
Management applicationUniFi Access: Version 1.22.17 and later




Related searches

Explore similar keywords in the DISTI catalog