Back to catalog
Cisco IE-2000U-16TC-GP Industrial Ethernet 2000 Series Switches
Cisco

Cisco IE-2000U-16TC-GP Industrial Ethernet 2000 Series Switches

Part No: IE-2000U-16TC-GP

AED 525$143 USD

Authorized B2B supply from DISTI Middle East (UAE & MENA). Genuine stock, project pricing, and fast regional dispatch.

Request a Quote

Specifications

Manufacturer
Cisco
Model
Cisco IE-2000U-16TC-GP
Manufacturer Part No
IE-2000U-16TC-GP

Alternate / cross-brand similar products

AI-matched alternatives based on specifications

Product description & technical overview

Cisco Cisco IE-2000U-16TC-GP

Specification
Total Ports
  • 18
RJ45 Ports
  • 16 FE
Combo Ports
  • 2 GE
Software
  • LAN Base
IEEE 1588
  • Yes
PRP
  • Yes
PoE
  • Yes
Hardware
  • 256 MB DRAM with ECC memory
  • 1 GB removable SD flash memory card (CG swap drive) – (128MB space available)
  • Mini-USB connector
Alarm
  • Alarm I/O: two alarm inputs to detect dry contact open or closed, one alarm output relay. 48 VDC, 0.5A max
Power Supply
  • Redundant DC input voltage with operating range: 12-48 VDC Nominal, 9.6-60 VDC Maximum
  • Maximum DC input current: 0.5A at 48 VDC, 1A at 24 VDC
Substation Compliance
  • IEC 61850-3
  • IEEE1613
Hazardous Location
  • ANSI/ISA 12.12.01 (Class 1, Div 2 A-D) (requires cabinet enclosure)
  • UL/CSA 60079-0, -15 (Class 1, Zone 2, group II gases, requires cabinet enclosure)
  • EN 60079-0, -15 ATEX certification (Class I, Zone 2, Group II gases, requires cabinet enclosure)
  • IEC 60079-0, -15 (Class I Zone 2, Group II gases, requires cabinet enclosure)
  • CSA 213
Industrial Control Safety
  • UL508
  • CSA C22.2 No. 142
EMC Interface Immunity
  • EN 55024 (CISPR 24)
  • AS/NZS CISPR 24
  • KN 24
  • IEC61000-4-2 (Criteria A – Class 2)
  • IEC61000-4-3/ENV50204 (Criteria A)
  • IEC61000-4-4 (Criteria A/Criteria B)
  • IEC61000-4-5 (Criteria B)
  • IEC61000-4-6 (Criteria A)
Standard Electromagnetic Emissions Certifications
  • FCC Part 15 Class A
  • EN 55022 Class A (CISPR22 Class A)
  • ICES-003 Class A
  • EN 300 386
  • VCCI Class A
  • AS/NZS CISPR22 Class A
  • CNS 13438 Class A
  • KN 22 Class A CE Marking
Standard Safety Certifications
  • UL 60950-1
  • CSA 60950-1
  • EN 60950-1
  • IEC 60950-1, CB report and certificate with all national differences
Operating Environment
  • Operating Temperature: -40C to +75C
  • -40C to +70C (Vented Enclosure – 40 LFM Air Flow)
  • -40C to +60C (Sealed Enclosure – 0 LFM Air Flow)
  • -34C to +75C (Fan or Blower equipped Enclosure – 200 LFM Air Flow)
  • -40 to +85C (IEC 60068-2-2 Environmental Type testing – 100 hours)
  • Operating altitude: -60 m (-200 ft) to 3,000 m (10,000 ft), de-rate maximum operating temperature per IEEE 1613-2009:
  • Relatve humidity: 5% to 95% non-condensing
Storage Environment
  • Temperature: -50C to +85C
  • Altitude: 15,100 ft (4600 m)
Protection Class Code
  • IP30 per EN60529