Belden
Belden GUCN812 Cable Universal OFC CLT
Part No: GUCN812
AED 1,132$308 USD
Authorized B2B supply from DISTI Middle East (UAE & MENA). Genuine stock, project pricing, and fast regional dispatch.
Request a QuoteSpecifications
- Manufacturer
- Belden
- Model
- Belden GUCN812
- Manufacturer Part No
- GUCN812
- Compatible Country
- Middle East, Africa, Iran, Dubai
- Country of Origin
- US
Alternate / cross-brand similar products
AI-matched alternatives based on specifications
Product description & technical overview
Belden Belden GUCN812
| Parameter | Specification |
|---|---|
| Fiber Type | OS2 |
| Fiber Grade (Acc. to ITU-T) | G.652D & G.657A1 |
| Fiber Count | 12 |
| Fiber Color Coding | TIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown, Gray, White, Red, Black, Yellow, Violet, Pink, Aqua |
| Subunit Waterblocking | Gel Filled |
| Subunit Diameter | 3.3 mm |
| Subunit Color | TIA coding (Gxxxxxx.T): Natural |
| Cable Core Water Blocking | Waterblocking Glass Yarns + Tape |
| Armor Type and Material | CST - Corrugated Steel Tape |
| Jacket Material | LSZH - Low Smoke Zero Halogen (Flame Retardant) |
| Nominal Diameter | 9.0 mm (0.35 in) |
| Optical Characteristics | |
| Wavelength | 1310 nm / 1550 nm / 1625 nm |
| Max. Attenuation | 0.39 dB/km / 0.24 dB/km / 0.29 dB/km |
| Mechanical Tests | |
| Min. Bend Radius (Installation) | 180 mm (IEC 60794-1-21-E6) |
| Min. Bend Radius (Operation) | 180 mm (IEC 60794-1-21-E11) |
| Max. Tensile Strength (Installation) | 2400 N (IEC 60794-1-21-E1) |
| Max. Tensile Strength (Operation) | 800 N (IEC 60794-1-21-E1) |
| Max. Crush Resistance (Installation) | 22 kN/m (IEC 60794-1-21-E3) |
| Max. Crush Resistance (Operation) | 11 kN/m (IEC 60794-1-21-E3) |
| Bulk Cable Weight | 104 kg/km (69.9 lbs/1000 ft) |
| Installation Temperature Range | -5 C to +50 C |
| Operating Temperature Range | -30 C to +55 C |
| Storage Temperature Range | -30 C to +55 C |
| Environmental Suitability | Indoor/Outdoor - Euroclass Dca |
| Flammability / Reaction to Fire | IEC 60332-1-2, IEC 60332-3-25 |
| Resistance to Fire | IEC 60331-25-E120 / EN 50200-PH120 ANNEX E |
| CPR Compliance | Euroclass: Dca-s1,d1,a1; UKCA Class: Dca-s1,d1,a1 |
| ISO/IEC Compliance | IEC 60794, ISO/IEC 11801-1 |
| European Halogen Free Standards | IEC 60754-1 & 60754-2; IEC 61034-2 |
| UK Regulation Compliance | UKCA Mark |