Back to catalog
Belden GUCN812 Cable Universal OFC CLT
Belden

Belden GUCN812 Cable Universal OFC CLT

Part No: GUCN812

AED 1,132$308 USD

Authorized B2B supply from DISTI Middle East (UAE & MENA). Genuine stock, project pricing, and fast regional dispatch.

Request a Quote

Specifications

Manufacturer
Belden
Model
Belden GUCN812
Manufacturer Part No
GUCN812
Compatible Country
Middle East, Africa, Iran, Dubai
Country of Origin
US

Alternate / cross-brand similar products

AI-matched alternatives based on specifications

Product description & technical overview

Belden Belden GUCN812

Parameter Specification
Fiber Type OS2
Fiber Grade (Acc. to ITU-T) G.652D & G.657A1
Fiber Count 12
Fiber Color Coding TIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown, Gray, White, Red, Black, Yellow, Violet, Pink, Aqua
Subunit Waterblocking Gel Filled
Subunit Diameter 3.3 mm
Subunit Color TIA coding (Gxxxxxx.T): Natural
Cable Core Water Blocking Waterblocking Glass Yarns + Tape
Armor Type and Material CST - Corrugated Steel Tape
Jacket Material LSZH - Low Smoke Zero Halogen (Flame Retardant)
Nominal Diameter 9.0 mm (0.35 in)
Optical Characteristics
Wavelength 1310 nm / 1550 nm / 1625 nm
Max. Attenuation 0.39 dB/km / 0.24 dB/km / 0.29 dB/km
Mechanical Tests
Min. Bend Radius (Installation) 180 mm (IEC 60794-1-21-E6)
Min. Bend Radius (Operation) 180 mm (IEC 60794-1-21-E11)
Max. Tensile Strength (Installation) 2400 N (IEC 60794-1-21-E1)
Max. Tensile Strength (Operation) 800 N (IEC 60794-1-21-E1)
Max. Crush Resistance (Installation) 22 kN/m (IEC 60794-1-21-E3)
Max. Crush Resistance (Operation) 11 kN/m (IEC 60794-1-21-E3)
Bulk Cable Weight 104 kg/km (69.9 lbs/1000 ft)
Installation Temperature Range -5 C to +50 C
Operating Temperature Range -30 C to +55 C
Storage Temperature Range -30 C to +55 C
Environmental Suitability Indoor/Outdoor - Euroclass Dca
Flammability / Reaction to Fire IEC 60332-1-2, IEC 60332-3-25
Resistance to Fire IEC 60331-25-E120 / EN 50200-PH120 ANNEX E
CPR Compliance Euroclass: Dca-s1,d1,a1; UKCA Class: Dca-s1,d1,a1
ISO/IEC Compliance IEC 60794, ISO/IEC 11801-1
European Halogen Free Standards IEC 60754-1 & 60754-2; IEC 61034-2
UK Regulation Compliance UKCA Mark